Air Quality Test Results

Should you find your cylinder has been contaminated by bad air, you should follow the guidelines below.

Before you dive.
Return cylinder to source of fill, explain cylinder is contaminated and ask Fill station Manager to check.
If you are happy with their response or actions, then proceed with their recommendations

Should a diver have breathed contaminated air at depth

  • Check diver for signs of CO poisoning
    i.e. Red finger nail beds, or inside of lips, headaches, dizziness, nausea or unconsciousness may also ensue.

  • Check divers LOC
  • Administer 100 % Oxygen, if available
  • Arrange transport to medical assistance preferably, HBC
  • Take contaminated cylinder with patient for analysis and divers' computor for dive profile.
  • Do not administer fluids, keep patient warm, not hot. (shock management)
  • Inform fill station of incident.
  • Maintain watch on patient until medical help arrives and inform officers, that patient has breathed compressed air at depth that is suspected of being contaminated.

    Express patient should be maintained on Oxygen for transport to hospital or HBC.

    To avoid breathing contaminated air, always test your air supply before use.

Step One: Have cylinder filled only at reputable air source.  Ask to sight latest air purity report, should be dated within three months.
Step Two: Smell supplied air before leaving fill station.
Step Three: Place white cloth or hanky over outlet, purge valve slightly and view for signs of rust or foreign material.
Step Four: Taste air for anything out of the ordinary, remembering air should not have any taste or odour.

How is your Breathing Air Quality Analysis Conducted?

As part of our quarterly scheduled analysis, your breathing gas requires a rigorous testing regime-
This analysis that gives an accurate report (at the time of testing) of your compressed breathing air being produced, onsite.

We test for the following components:

Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Water Vapour (H2O)
Oil Mist
Delivered Air Odour Quality

Should a high reading be found, a quality assessment is made and the problem rectified.
All results are accurate at time of testing.

 

Pro-Dive Central Coast is proud of the fact, their quality of supplied Air easily meets and exceeds Australian Standards.

So are our clients, they also include:

  • Research Diving Network
  • NSW Rural Fire Brigade
  • Wyong Shire Council
  • Gosford Shire Council
  • Gosford Fire Services, Rural Division
  • Sanitarium Australia
  • Masterfoods Australia
  • Albany International
  • Kariong Rural Fire Brigade
  • Lake Munmorah Rural Fire Brigade
  • Chittaway Rural Fire Brigade
  • Charmhaven Rural Fire Brigade
  • Norah Head Treatment works
  • Bateau Bay Treatment works


    Air Quality Management Test Results

     December 2017              Tested By: Bob Diaz
    Testing Allowance  Result
    Carbon Monoxide <10 ppm 0 ppm
    Oil <1 mg/m3 0 mg/m3
    Odours Slight None
    Water < 100 mg/m3 55 mg/m3
    Carbon Di Oxide 500 ppm 60 ppm
         23.12.18


    Air Quality Management Test Results

     January 2018              Tested By: Bob Diaz
    Testing Allowance  Result
    Carbon Monoxide <10 ppm <2 ppm
    Oil <1 mg/m3 0 mg/m3
    Odours Slight None
    Water < 100 mg/m3 40 mg/m3
    Carbon Di Oxide 500 ppm 50 ppm
         31.01.18

Air Quality Management Test Results

February 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm 0 ppm
Oil <1 mg/m3 0 mg/m3
Odours Slight None
Water < 100 mg/m3 40 mg/m3
Carbon Di Oxide 500 ppm 50 ppm
     22.02.18

 

 

Air Quality Management Test Results

 March 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm <1 ppm
Oil <1 mg/m3  0 mg/m3
Odours Slight None
Water < 100 mg/m3 35 mg/m3
Carbon Di Oxide 500 ppm 70 ppm
     29.03.18

 

Air Quality Management Test Results

 April 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm <1 ppm
Oil <1 mg/m3 0 mg/m3
Odours Slight None
Water < 100 mg/m3 40 mg/m3
Carbon Di Oxide 500 ppm 50 ppm
     30.04.18

 

Air Quality Management Test Results

 May 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm  <1 ppm
Oil <1 mg/m3  0 mg/m3
Odours Slight  None
Water < 100 mg/m3  60 mg/m3
Carbon Di Oxide 500 ppm  70 ppm
     29.05.18

 

 

   

 

Air Quality Management Test Results

 June 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm  <1 ppm
Oil <1 mg/m3  0 mg/m3
Odours Slight  None
Water < 100 mg/m3  55 mg/m3
Carbon Di Oxide 500 ppm  70 ppm
     29.06.18

 

 

Bi - monthly Air Quality testing regime

 

 August 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm  ppm
Oil <1 mg/m3  mg/m3
Odours Slight  
Water < 100 mg/m3  mg/m3
Carbon Di Oxide 500 ppm  ppm
     

 

Air Quality Management Test Results

 Octoberr 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm  ppm
Oil <1 mg/m3  mg/m3
Odours Slight  
Water < 100 mg/m3  mg/m3
Carbon Di Oxide 500 ppm  ppm
     

 

Air Quality Management Test Results

 December 2018              Tested By: Bob Diaz
Testing Allowance  Result
Carbon Monoxide <10 ppm  ppm
Oil <1 mg/m3  mg/m3
Odours Slight  
Water < 100 mg/m3  mg/m3
Carbon Di Oxide 500 ppm  ppm